Designed to be installed on the wall or on a rolling shutter casing, the EHT humidity sensitive air inlet is an ideal alternative to window-mounted air inlets. It thus solves the problem of lack of space on windows. With accessories, it provides a high level of acoustic protection, up to 52 dB attenuation. A closing device and an airflow controller can be used to protect from cold weather and strong winds.
Humidity sensitive system: modulates the airflow according to the local relative humidity.
Core drilling: easy installation on the wall, ideal for refurbishment projects.
Acoustic attenuation: up to 52 dB with accessories.
Easy to maintain: no adjustment, simple yearly dusting, and readily accessible filters.
Easy to install, in particularly in refurbishment, the circular hole can be made using a core drill 100 mm in diameter – 125 mm for the complete acoustic kit. The complete acoustic kit (EHT + 125 mm duct + acoustic foam + acoustic canopy) can attain an acoustic attenuation of 52 dB, which places it among the best products available on the market.
Nothing could be easier than cleaning the insect filter: once the EHT is unclipped, the removable F-EHT filter is readily accessible from the interior of the dwelling.
The ACW makes it possible to limit the maximum airflow to 40 m3/h in a duct 100 or 125 mm in diameter, even when the pressure exceeds 20 Pa (when there is wind for example).
Air inlet | EHT 5-40 | EHT 11-40 | EHT 17-40 | EFT24 | EFT 40 | |
Standard code | EHT780 | EHT957 | EHT022 | EFT840 | EFT026 | |
Airflow characteristics | ||||||
Humidity sensitive | ■ | ■ | ■ | – | – | |
Closing device | ■ | – | – | – | – | |
Airflow (min – max) @ 10 Pa | m3/h | 5-40 | 11-40 | 17-40 | 24 | 40 |
Max. opening area | mm2 | 4 000 | 4 000 | 4 000 | 4 000 | 4 000 |
Accessories / composition of the kits | ||||||
Air inlet (EHT) | ■ | ■ | ■ | ■ | ■ | |
ø100 mm tube, length 350 mm | ◊ | ◊ | ◊ | ◊ | ◊ | |
Acoustic foam for ø100 mm tube | ◊ | ◊ | ◊ | ◊ | ◊ | |
Acoustic foam for ø125 mm tube | ◊ | ◊ | ◊ | ◊ | ◊ | |
Anti-insect removable filter (F-EHT) | ◊ | ◊ | ◊ | ◊ | ◊ | |
Acoustic foam for A-EHT canopy | ◊ | ◊ | ◊ | ◊ | ◊ | |
Anti-insect wall standard canopy (A-EHT-AM) | ◊ | ◊ | ◊ | ◊ | ◊ | |
Wall standard canopy (A-EHT) | ◊ | ◊ | ◊ | ◊ | ◊ | |
Characteristics | ||||||
Weight | g | 489 | 489 | 489 | 382 | 382 |
Colour | white | white | white | white | white | |
Material (main) | PS | PS | PS | PS | PS | |
Installation | ||||||
Spigot* | mm | ø100 | ø100 | ø100 | ø100 | ø100 |
Wall passage dimensions | mm | ø100 or ø125 | ø100 or ø125 | ø100 or ø125 | ø100 or ø125 | ø100 or ø125 |
Rolling shutter casing installation | ■ | ■ | ■ | ■ | ■ | |
Wall installation | ■ | ■ | ■ | ■ | ■ | |
Destination room | bedroom / living room |
■: standard / included
◊: compatible
*Exists in bracket version
Available kits
Kits | Wall kit EHT 5-40 #1 | Wall kit EHT 5-40 #2 | Acoustic wall kit EHT 5-40 | |
Standard code | EHT816 | EHT815 | EHT969 | |
Airflow characteristics | ||||
Humidity sensitive | ■ | ■ | ■ | |
Closing device | ■ | ■ | ■ | |
Airflow (min – max) @ 10 Pa | m3/h | 5-40 | 5-40 | 5-40 |
Max. opening area | mm2 | 4000 | 4000 | 4000 |
Accessories / composition of the kits | ||||
Air inlet (EHT) (1) | ■ | ■ | ■ | |
ø100 mm tube, length 350 mm (2) | ■ | ■ | ■ | |
Acoustic foam for ø100 mm tube (3) | – | – | ■ | |
Acoustic foam for ø125 mm tube (4) | – | – | – | |
Anti-insect removable filter (F-EHT) (5) | – | ■ | – | |
Acoustic foam for A-EHT canopy (6) | – | – | ■ | |
Anti-insect wall standard canopy (A-EHT-AM) | ■ | – | ■ | |
Wall standard canopy (A-EHT) (7) | – | ■ | – | |
Characteristics | ||||
Weight | g | 862 | 962 | 988 |
Colour | white | white | white | |
Material (main) | PS | PS | PS | |
Installation | ||||
Spigot* | mm | ø100 | ø100 | ø100 |
Wall passage dimensions | mm | ø100 | ø100 | ø100 |
Rolling shutter casing installation | – | – | – | |
Wall installation | ■ | ■ | ■ | |
Destination room | bedroom / living room |
■: standard / included
◊: compatible
*Exists in bracket version
Acoustic performances of the different kits
Acoustics (combinations) | Comb n.1 | Comb n.2 | Comb n.3 | Comb n.4 | Comb n.5 | Comb n.6 |
EHT air inlet, max. opening = 40 m3/h @ 10 Pa (1) | ■ | ■ | ■ | ■ | ■ | ■ |
ø100 mm tube (2) | ■ | ■ | ■ | ■ | – | – |
Acoustic foam for ø100 mm tube (3) | – | ■ | – | ■ | – | – |
ø125 mm tube | – | – | – | – | ■ | ■ |
Acoustic foam for ø125 mm tube (4) | – | – | – | – | ■ | ■ |
Acoustic foam for A-EHT canopy (6) | – | – | ■ | ■ | – | ■ |
A-EHT wall canopy (7) | ■ | ■ | ■ | ■ | ■ | ■ |
Dn,e,w (C ; Ctr) Acoustic attenuation in dB | 33 (0 ; 0) | 42 (0 ; -2) | 40 (0 ; -2) | 45 (0 ; -2) | 49 (-1 ; -4) | 52 (-1 ; -4) |
Note: acoustics results for recommanded slots.
IMAGE | CODE | DESIGNATION |
---|---|---|
![]() ![]() |
AEA776 | ø100 mm tube Wall plastic sleeve ø100 mm, L.350 mm for EHT |
![]() ![]() |
AEA775 | A-EHT Wall canopy |
![]() ![]() |
AEA064 | ACW Airflow controller: limits the airflow to 40 m3/h |
![]() ![]() |
AEA774 | F-EHT Removable filter for ø100 mm tube |
![]() ![]() |
AEA086 | ø125 mm adaptor for ACW related product |
![]() ![]() |
AEA967 | Acoustic foam for ø125 mm duct, 48 dB (x2 kit) |
![]() ![]() |
AEA968 | Acoustic foam for ø100 mm duct, 43 dB (x2 kit) |